Brand Name : Fanke
Model Number : CHX-4800KVA/200KV,400KV,600KV,800KV
Certification : ISO9001
Place of Origin : CHINA
MOQ : One Set
Price : Negotiable
Payment Terms : L/C, T/T
Supply Ability : 5 sets / 2months
Delivery Time : 45~60 working days
Packaging Details : Export standard wooden case with fumigation free
Test Principle : Variable Frequency Resonant Circuit
Usage : On-site AC Withstand Voltage Test
Design Feature : Highed Voltage Modular Test Reactor, Higher Q Value Output ,Multiple Test Range
Component : V/F Power Source, Excitation Transformer,lighter Modular Test Reactor, And Voltage Divider
Test Frequency : 30-300Hz
Duty Cycle : 15mints or 60 Mints
Test Accuracy : No Less Than 1.5%
Output Waveform : Good Sine Wave
Special For : On-site Test For UHV GIS , GIL , CT, PT
Test Standard : IEC60060-1:2010;IEC 62271-203:2011 for GIS
Variable Frequency Resonant Withstand Voltage Test Set , High Voltage Test Set For UHV Substation or GIS
I. Application :
 This series of test system mainly aims at AC voltage withstand test of primary equipment of large capacitor and high voltage and can also satisfy field AC voltage withstand test of sorts of capacitance apparatus. HV test reactors use combined series-parallel patterns which not only meet the requirements of voltage withstand of HV transformer, GIS, SF6 breakers,mutual inductions and bushings but also that of long distance XLPE cables ,with compatibility of extensive tests to be a desired voltage withstand test device for power supply system overhauling and electric power engineer construction units.
The above picture is for variable series resonance test system of 5000KVA/1000KV on test field in Shanxi Jindongnan Substation, testing HV
 GIS of 1000KV class UHV line in domestic.
Applicable objects
 - Long distance XLPE cables with 110KV,220KV,500KV class
 - HV GIS or GIL, HV coupling capacitor,capacitor voltage transformer of no more than 1000KV class
 - Assembling capacitor(test frequency pledges in 45—65Hz)
  
II. Main Components:(4000KVA/1000KV test system for example)
| SN | Name of Components | Type and specification | Qty. | Each weight | Each Dimension | 
| 1 | Variable frequency power | FKVF-200kW/380V | 1piece | 180kgs | 750*700*1000mm | 
| 2 | Excitation transformer | CQSB(J)-200kVA | 1piece | 1800kgs | 650*650*800mm | 
| 3 | HV resonant test reactor | CHX(kf)-800kVA/200kV | 5pieces | 2800kgs | D1200*H1250mm | 
| 4 | Capacitive divider | TRF-1000kV/1000pF | 1set | 550kgs | D350*H7600mm | 
| 5 | Special test accessories | 1set | 
Note:1.Load capacitantor can be optional when small load line is tesing or need analog load to control test frequency .
2.Test reactor can be produced to be 150KV,200KV,250KV,300KV, 350KV, 400KV for each piece rated voltage according to different tested object scope or customer requried. The max. rated current of each HV reactor can be 1~15A optional in this serialized set,
3. HV Damping inductance can be optional for suppressing high frequency harmonics and resisting overvoltage caused from tested object flashover, special in EHV or UHV test set.
III. Test priciple :
 
 
 VF: Variable Frequency Power Source T : Excitation Transformer
 L : Test Reactor Cx: Tested Equipment MOA1: Lightning Arrestor
 C1,C2: Voltage divider(C1 is high voltage arm,C2 is low voltage arm )
 
 
 IV. General Technical Data:
 V. Technical Feature and advantage
VI. Main Measuring and control software panel as following :
 
 VII.Accessories
 VIII. Other Typical Model
1 For 123KV ~300KV class GIS on-site AC hipot test
| Model | Rated voltage | Rated output current | Rated output capacity | Application (From 45Hz starting) | 
| CHX-400KVA/200KV,400KV | 200KV*2 | 2A@200KV | 400KVA | For 123KV and below class GIS | 
| 1A@400KV | For 300KV and below class GIS | |||
| CHX-800KVA/200KV,400KV | 200KV*2 | 4A@200KV | 800KVA | For 123KV and below class GIS | 
| 2A@400KV | For 300KV and below class GIS | |||
| CHX-1000KVA/200KV,400KV | 200KV*2 | 5A@200KV | 1000KVA | For 123KV and below class GIS | 
| 2.5A@400KV | For 300KV and below class GIS | |||
| CHX-2000KVA/200KV,400KV | 200KV*2 | 10A@200KV | 2000KVA | For 123KV and below class GIS | 
| 5A@400KV | For 300KV and below class GIS | |||
| Special requirement can be made by order | ||||
2 For 145KV ~362KV class GIS on-site AC hipot test
| Model | Rated voltage | Rated output current | Rated output capacity | Application (From 45Hz starting) | 
| CHX-500KVA/250KV,500KV | 250KV*2 | 2A@250KV | 500KVA | For 145KV and below class GIS | 
| 1A@500KV | For 362KV and below class GIS | |||
| CHX-1000KVA/250KV,500KV | 250KV*2 | 4A@250KV | 1000KVA | For 145KV and below class GIS | 
| 2A@500KV | For 362KV and below class GIS | |||
| CHX-2000KVA/250KV,500KV | 250KV*2 | 8A@250KV | 2000KVA | For 145KV and below class GIS | 
| 4A@500KV | For 362KV and below class GIS | |||
| CHX-3000KVA/250KV,500KV | 250KV*2 | 12A@250KV | 3000KVA | For 145KV and below class GIS | 
| 6A@500KV | For 362KV and below class GIS | |||
| Special requirement can be made by order | ||||
 3 For 170KV ~550KV class GIS on-site AC hipot test
| Model | Rated voltage | Rated output current | Rated output capacity | Application (From 45Hz starting) | 
| CHX-1200KVA/300KV,600KV | 300KV*2 | 4A@300KV | 1200KVA | For 170KV and below class GIS | 
| 2A@600KV | For 550KV and below class GIS | |||
| CHX-1800KVA/300KV,600KV | 300KV*2 | 6A@300KV | 1800KVA | For 170KV and below class GIS | 
| 3A@600KV | For 550KV and below class GIS | |||
| CHX-2400KVA/300KV,600KV | 300KV*2 | 8A@300KV | 2400KVA | For 170KV and below class GIS | 
| 4A@600KV | For 550KV and below class GIS | |||
| CHX-3600KVA/300KV,600KV | 300KV*2 | 12A@300KV | 3600KVA | For 170KV and below class GIS | 
| 6A@600KV | For 550KV and below class GIS | |||
| CHX-4800KVA/300KV,600KV | 300KV*2 | 16A@300KV | 4800KVA | For 170KV and below class GIS | 
| 8A@600KV | For 550KV and below class GIS | |||
| Special requirement can be made by order | ||||
 4 For 123KV ~800KV class GIS on-site AC hipot test
| Model | Rated voltage | Rated output current | Rated output capacity | Application (From 45Hz starting) | 
| CHX-2400KVA/200KV×4 | 800KV | 12A@200KV | 2400KVA | For 123KV and below class GIS | 
| 6A@400KV | For 300KV and below class GIS | |||
| 3A@600KV | For 550KV and below class GIS | |||
| 3A@800KV | For 800KV and below class GIS | |||
| CHX-3600KVA/200KV×4 | 800KV | 13A@200KV | 3600KVA | For 123KV and below class GIS | 
| 9A@400KV | For 300KV and below class GIS | |||
| 4.5A@600KV | For 550KV and below class GIS | |||
| 4.5A@800KV | For 800KV and below class GIS | |||
| CHX-4800KVA/200KV×4 | 800KV | 24A@200KV | 4800KVA | For 123KV and below class GIS | 
| 12A@400KV | For 300KV and below class GIS | |||
| 6A@600KV | For 550KV and below class GIS | |||
| 6A@800KV | For 800KV and below class GIS | |||
| Special requirement can be made by order | ||||
IX. On-site insulation test standard table from IEC 62271-203:2011 for HV GIS

|   | 
| Variable Frequency AC Resonant Test System , High Voltage Test Set For UHV Substation Or GIS Images | 
 High Accuracy Hv Voltage Tester , High Voltage Apparatus For Power Substation
                                                                                    
                        
                        
                        
                                                            High Accuracy Hv Voltage Tester , High Voltage Apparatus For Power Substation
                                                    
                        
                     810KVA High Voltage Test Kit , 35KV And 132KV Hv Cable Testing Equipment 30
                                                                                    
                        
                        
                        
                                                            810KVA High Voltage Test Kit , 35KV And 132KV Hv Cable Testing Equipment 30
                                                    
                        
                     45KV 270KV AC Resonant Test System For 35KV Cable And 110KV Power Substation
                                                                                    
                        
                        
                        
                                                            45KV 270KV AC Resonant Test System For 35KV Cable And 110KV Power Substation
                                                    
                        
                     132KV GIS Testing AC Resonant Test System Lighter Single Piece Weight
                                                                                    
                        
                        
                        
                                                            132KV GIS Testing AC Resonant Test System Lighter Single Piece Weight
                                                    
                        
                     FKVF Series High Voltage Testing Of Electrical Equipments 5KW~400KW Capacity
                                                                                    
                        
                        
                        
                                                            FKVF Series High Voltage Testing Of Electrical Equipments 5KW~400KW Capacity
                                                    
                        
                     High Accuracy Thermal Generator Test Equipment / Ac High Voltage Tester Low
                                                                                    
                        
                        
                        
                                                            High Accuracy Thermal Generator Test Equipment / Ac High Voltage Tester Low
                                                    
                        
                     30-300Hz Frequency High Voltage Resonant Test System With V/F Power Source
                                                                                    
                        
                        
                        
                                                            30-300Hz Frequency High Voltage Resonant Test System With V/F Power Source
                                                    
                        
                     Power Frequency AC Resonant Test System For EHV CVT And CB Rutine Testing
                                                                                    
                        
                        
                        
                                                            Power Frequency AC Resonant Test System For EHV CVT And CB Rutine Testing
                                                    
                        
                     380V AC Resonant Test System Power Frequency Resonant Intelligent Control Unit
                                                                                    
                        
                        
                        
                                                            380V AC Resonant Test System Power Frequency Resonant Intelligent Control Unit
                                                    
                        
                     2100kVA Adjusting Inductance Type Series Resonance Test system
                                                                                    
                        
                        
                        
                                                            2100kVA Adjusting Inductance Type Series Resonance Test system